Instruction book Audi A3 Version Year 2014
Engine Oil 1L Longlife - Audi Fleecejacke - Audi Mug Audi Beanie - Audi all-weather floor mats Genuine Audi Interior Cargo Organizer
Audi A3  Setting off  e-tron  Charging the Audi A3 with the Audi e-tron charging system
Charging system: Operating unit
Fig. 1 Charging system: Operating unit
Radiator grille: Vehicle charging connection and buttons
Fig. 2 Radiator grille: Audi A3 charging connection and buttons
Applies to Audi A3s: with plug-in hybrid drive
You can check the operating status by looking at the LED -A-, the display on the operating unit -B- Fig. 1 and the status LED -2- Fig. 2.
(A) Symbol
(B) Fault code
(C) LED on operating unit -A-
(D) Meaning
(E) Remedy
(A)
(B)
(C)
(D)
(E)


blue
flashing
Self-test



green
lit
Cable connected correctly



flashing
Cable connected and charging



white
lit
Self-test successfully completed; cable not connected or incorrectly connected to Audi A3 charging connection.
Connect the cable correctly.

330 or 340
red
lit
Cable not connected correctly or defective.
Check the cable and reconnect it or replace the cable.

450, 500, 460, 200, 210, 220, 410 or 490
red
lit
Fault in the operating unit.
Disconnect the operating unit from the mains and have the fault rectified by a qualified workshop.

180
red
lit
Operating unit overheated or too cold
Allow the operating unit to cool down or use it within the specified temperature range.

140 or 130
red
lit
Communication fault with Audi A3.
Have the fault rectified by a qualified workshop.

300, 310 or 370
red
lit
Fault in domestic installation.
Have the electrical installation checked by a qualified electrician.

110
red
flashing
Residual current circuit breaker (RCCB) in operating unit tripped.
Reset the RCCB with the OK button -D- Fig. 1. Have the electrical installation checked by a qualified electrician if the fault is indicated again.
Table  Charging system: Operating unit
(A) LED on the Audi A3 -2-
(B) Meaning
(C) Remedy
(A)
(B)
(C)
green
lit
High-voltage battery charge cycle finished.
Unplug the charging connector, fit the cap and close the cover on the charging unit.
lit (pulsating)
High-voltage battery is charging or air conditioning is on.

flashing (for approx. one minute after leaving the Audi A3)
Charging timer has been programmed but charging cycle has not yet started. The LED in the button -1- Fig. 2 will light up in addition.

yellow
lit
Charging cable connected but no mains power detected.
Have the power supply or mains checked. Check the status indicators on the operating unit Table "Charging system: Operating unit". Obtain professional assistance if necessary.
flashing
Selector lever is not in position P.
Move the selector lever to position P.
red
lit
Charging connector not properly locked in Audi A3 charging connection.
Check that the charging connector is plugged in correctly Link. Unplug the charging connector and plug it into the charging connection again. Obtain professional assistance if necessary.
flashing
Charging system fault. High-voltage battery cannot be charged.
Obtain professional assistance if necessary.
Table  Audi A3: Charging unit
Engine Oil 1L Longlife - Audi Fleecejacke - Audi Mug Audi Beanie - Audi all-weather floor mats Genuine Audi Interior Cargo Organizer